TaurusFix

ISO 16582 dimensions — Open end blind rivets with break pull mandrel and protruding head, Cu/St or Cu/Br or Cu/SSt

Edition
2002 edition, current
Related
ISO 14588ISO 14589ISO 3269

ISO 16582 dimensions

mm · 4 sizes, 3 – 4.8In stock
SizedkHead diameterkHead heightdBody diameterdmMandrel diameterpMandrel lengthbBlind length additiondh1Clearance hole
minnom.minmaxmaxminmaxminmax
36.35.41.32.853.082253.53.13.2
6.75.81.33.053.2822543.33.4
8.46.91.73.854.082.452544.14.2
4.810.18.324.654.882.95274.54.95

Dimensions from ISO 16582:2002, the current edition.

Load values — Table 3 — Mechanical properties

N · ISO 16582:2002 §5 Table 3
SizeMinimum shear loadMinimum tensile load
3760950
3,28001000
415001800
4,820002500

Load values — Table 3 — Mandrel break load

N · ISO 16582:2002 §5 Table 3
SizeMaximum mandrel break load
33000
3,23000
44500
4,85000

Load values — Clause 6 — Mandrel push-out resistance

N · ISO 16582:2002 §6
SizeMandrel push-out resistance (min.)
all sizes10

Load values — Table 4 — Mandrel head retention test loads

N · ISO 16582:2002 §7 Table 4
SizeHead retention test load
315
3,215
420
4,825
Quote list0 lines

Your list is empty.